datasheetdetails
|
<< | < | AX-ANA-LPP - PH Sensor
|
|
The AX-ANA-LPP-xxx is an analytical sensor for the measurement of acidity (pH>7) and alkalinity (pH<7) in liquids. The potential difference between the submerged and reference probe generates a voltage proportional to the concentration of the hydrogen ions in the measured fluid. The long term stability and accuracy of the measurement requires a periodic calibration of the sensor using the standard buffer solutions. There is the option of a relay and/or an LCD display module. Its applications include water quality monitoring, water production, water waste treatment, within the pharmaceutical industry and within the food and beverage industry. |
Product Features
| • Measuring range pH 0-14 • Easy to set-up
| • Mounted on top of a tank • Variety of probes avaliable
|
Measuring range
| 0-14pH, reserve +/-2
| Resolution
| 0.01pH (internal resolution 0.004pH)
| Accuracy
| 0.1% of the measured value +/- 1 digit +/- 0.01% /Deg C
| Measuring Rate
| 300msec, on the display (refreshing rate) 1 sec
| Process Temperature
| -50 to +100 degC (semi-conductive sensor)
| Power Supply
| 12 to 36Vdc 720mW galvanically isolated, protected against surge transients
| Probes - LPP-111-X
| 1-12pH, 6 bar, 80 C, with solid particles
| Probes - LPP-121-X
| 1-12pH, 8bar, 80C, clear liquid
| Probes - LPP-131-X
| 1-12pH, 16bar@25C, 100C, with solid particles
| Probes - LPP-141-X
| 3-14pH, 6bar, 100C, clear liquid
| Probes - LPP-151-X
| 1-12pH, 0.5bar, 60C, clear liquid
| Probes - LPP-161-X
| 1-12pH, 3bar, 60C, clear liquid
| Probes - LPP-171-X
| 1-12pH, 6bar, 80C, clear liquid
| Probes - LPP-181-X
| 1-12pH, 3bar, 60C, clear liquid horizontally mountable
| Output - LPP-1X1-4
| HART and 4-20mA
| Output - LPP-1X1-8
| HART and 4-20mA EeX
| Output - LPP-1X1-H
| HART and 4-20mA and 1 x SPDT 1A at 30Vdc
| Display (option) SAP300
| Full featured programming LCD Display
| Intrinsically Safe Class
| ATEX II 1 G Exia B T6 Ga
| Cable Length
| 5m provided
| Weatherproof Rating
| IP68
| Materials, Housing
| Plastic
| Process Connection
| 1 1/2" BSP Polyproylene as standard ( PVDF option at additional cost) NPT option
| Electromagnetic Compatability
| EN61326 Class B
| Country of Origin
| EU
|
AX-ANA-LPP.pdf / Analytical sensor -pH |  |
|
|
|